8000系列模块化高压电源

型号:8000系列高压电源模块

功率:20W 50W 80W 100W 120W

输入电压:85V AC -265V AC

输出电压:1kV 2kV 5kV 10kV 15kV 20kV 30kV 40kV 50kV

产品详细介绍

 


Genvolt 8000系列是一款坚固耐用的模块化系列直流高电压供应范围,  电源输入电压从85V AC- 265V AC   50/60Hz。输出功率从1 kv - 70 kv选项。
  
Genvolt 8000系列具有主动升压型功率因数校正前端——即有源整流器。在主电源频率下提供非常低的谐波失真,功率因数高达0.99。
 
Genvolt  8000系列模块化高压电源具有唯一的固定极性,(正极性 或负极性)。采购是需确定电源极性。
  
Genvolt  8000系列高压电源模块具有恒压员工作模式和恒流源工作模式 两种工作模式, 并且可以快速切换两种工作模式。
  
Genvolt  8000系列模块化高压电源具有 输出短路保护 或电弧保护,,温度保护和过压保护  ,能够在苛刻的环境中使用。
 



The Genvolt 8000 series is a rugged modularised range of AC-input DC High Voltage supplies, designed to operate from a universal mains input from 85VAC to 256VAC 50/60Hz. Power Output options from 1kv to 70kV.

They feature an active boost-style Power Factor Correction front end – i.e. an active rectifier. This offers a very low harmonic distortion at mains frequencies with a power factor of up to 0.99.

The modules have a FIXED polarity output which should be specified at the time ordering using the “Model Finder” table.

They operate in both Voltage Control and Current Control modes with fast active crossover between the modes.

Protection against output short circuits or arcs, over temperature and output overvoltage allow for operation in demanding environments.

Input Specification

AC Input voltage range 85VAC to 256VAC, 47 – 63 Hz
Power Factor FL 0.99 NL 0.98
Output Polarity +ve or –ve (Please specify when ordering)
Voltage Load Regulation 0.01% of full voltage for a no load to a full load change
Voltage Line Regulation +/- 0.005% of full voltage over the specified input voltage range
Current Load Regulation 0.01% from 0V to full voltage
Current Line Regulation +/- 0.01% of full current over the specified input voltage range per 8 hours after
Voltage Ripple: 0.1% p-p of output voltage
Current Stability 0.02% per 8hrs after ½hr warm up
Temperature Coefficient 100 ppm per oC
Temperature Operating 0oC to 45o
Storage -20oC to +85oC
Interlock Open Interlock will shut down unit
Circuit Protection  Overvoltage, Overcurrent, Arcing and Over temperature
Relative Humidity  Non condensing

The control signal is NOT a safety interlock and must NOT be used for a protection system from high voltage generation for safety purposes.

Standard Features, as fitted at the factory

Control Logic level for high voltage enable/disable.
Overvoltage Protection Overvoltage conditions can be caused by excessive input program signal. If an overvoltage condition is detected, the power supply is latched off until input power is reset.
PS Fault Condition A PS fault indicator and a PS fault output on J1, indicate an OVP or a regulation error.
PF and Universal Input The input voltage of the 8000 can operate within the range from 85VAC to 265VAC. The power factor is actively corrected across the entire range and is better than 0.99 at full load.
Internal EMI Filter An internal EMI filter and fuse provide protection against line voltage surges and power supply faults

Remote Operating Features

Remote Programming Allows remote adjustment of the output voltage and current, via an external voltage source.   
Remote Monitor Allows remote monitoring of the output voltage and current.
High Voltage Enable/Disable Allows remote ON/OFF control of the high voltage.
+10VDC Reference A +10VDC is provided for remote programming via a potentiometer or voltage divider.

Mechanical Details

Weight Model specific, approximately 3Kgs 
Dimensions 95.25mm (H) x 127mm (W) x 279.4mm (D)
Power Input Connector IEC320 with mating connector x 2 Metres
HV Output Connector Proprietary HV Connector
Control Interface Connector 15 pin ‘D’ connector (Male)

Regulatory Approvals

  • Compliant to 2004/108/EC, the EMC directive
  • 2006/95/EC, the low voltage directive
  • RoHS compliant and CE approved
Maximum Voltage Maximum Current Polarity Model Number
1kV 120mA P or N 80120P (+ve) or 80120N (-ve)
5kV 24mA P or N 8024P (+ve) or 8024N (-ve)
10kV 12mA P or N 8012P (+ve) or 8012N (-ve)
20kV 6mA P or N 806P (+ve) or 806N (-ve)
30kV 4mA P or N 804P (+ve) or 804N (-ve)
40kV 3mA P or N 803P (+ve) or 803N (-ve)
50kV 2.4mA P or N 8050P (+ve) or 8050N (-ve)
60kV 2mA P or N 8060P (+ve or 8060N (-ve)
70kV 1.7ma P or N 8070P (+ve) or 8070N (-ve)

Typical applications include:

  • Electrospinning & Electrospraying
  • X-ray Generation
  • Insulation Testing
  • Capacitor Charging (contact Genvolt for individual applications)
  • Laboratory Use